Description
Hanna Instruments HI97115UC Marine Master Multiparameter Checker
Marine Master Waterproof Wireless Multiparameter Photometer w/Bluetooth Connection to the Hanna App where you can save your results.
pH (HI780)
Alkalinity (HI772)
Ammonia (HI784)
Calcium (HI758)
Magnesium (HI783)
Nitrate High Range (HI782)
Nitrite Ultra Low Range (HI764)
Phosphate Ultra Low Range (HI774)
Chemicals Reagent Starter Kits for all tests and a Sweet Carrying Case
The HI97115 is suitable for field and bench measurements. The HI97115 can be used as a stand-alone photometer or can be connected to the Hanna Lab App with a compatible smart device via the integrated Bluetooth module. When connected, Hanna Lab App functions include measurement with the ability to add notes, data logging with extended storage capacity, data sharing, and the ability to create and save method groups.
• Precise and advanced LED optical system• Waterproof and floating IP67 meter design• Meter validation using certified CAL Check™ cuvettes• Includes auto data logging features to easily record up to 200 water testing results• On-screen tutorial mode guides users step-by-step through the measurement process• Option to assign locations to logged readings• Positive-locking system ensures that the cuvettes are placed into the holder in the same position every time• Future compatibility with Hanna Cloud
Specifications
Marine pH
Range
6.3 to 8.6 pH
Resolution
0.1 pH
Accuracy
±0.2 pH of reading at 25 °C
Method
Colorimetric Adaptation of the Phenol Red Method
LED
525 nm
Marine Alkalinity
Range
0.0 to 20.0 dkH
Resolution
0.1 dkH
Accuracy
±0.3 dKH ±5 % of reading at 25 °C
Method
Colorimetric Method
LED
610 nm
Marine Ammonia
Range
0.00 to 2.50 ppm (as NH₃)
Resolution
0.01 ppm
Accuracy
±0.05 ppm 5% of reading at 25 °C
Method
Adaptation of the Salicylate Method
LED
610 nm
Marine Calcium
Range
200 to 600 ppm
Resolution
1 ppm
Accuracy
±6% of reading at 25 °C
Method
Adaptation of the Zincon Method
LED
610 nm
Marine Magnesium
Range
1000 to 1800 ppm (as Mg2+)
Resolution
5 ppm
Accuracy
±5% of reading at 25 °C
Method
Adaptation of the Colorimetric EDTA Method
LED
610 nm
Marine Nitrate HR
Range
0.0 to 75.0 ppm (as NO₃–)
Resolution
0.1 ppm
Accuracy
±2.0 ppm ±5% of reading at 25 °C
Method
Zinc Reduction Method
LED
525 nm
Marine Nitrite ULR
Range
0 to 200 ppb (as NO₂–-N)
Resolution
1 ppb
Accuracy
±10 ppb ±4% of reading at 25 °C
Method
Adaptation of the EPA Diazotization Method 354.1
LED
525 nm
Marine Phosphate ULR
Range
0.00 to 0.90 ppm
Resolution
0.01 ppm
Accuracy
±0.02 ppm ±5% of reading at 25 °C
Method
Adaptation of Standard Methods for the Examination of Water and Wastewater, 20th Edition, Ascorbic Acid Method
LED
610 nm
Measurement System
Light source
LED
Bandpass filter
wavelength 525 nm & 610 nm bandwidth 8 nm wavelength accuracy ±1.0 nm
Light detector
silicon photocell
Cuvette Type
round 24.6 mm diameter (22 mm inside diameter)
Additional Specifications
Auto logging
200 readings
Display
128 x 64 pixel B/W LCD with backlight
Auto-of
after 15 minutes of inactivity (30 minutes before a READ measurement)
Battery type / Life
alkaline 1.5 V AA (3) / > 800 measurements (without backlight)
Environment
0 to 50 °C (32 to 122 °F); 0 to 100% RH, nonserviceable
Dimensions
142.5 x 102.5 x 50.5 mm (5.6 x 4.0 x 2.0″)
Weight
380 g (13.4 oz.); with batteries
Casing
IP67 rating, floating
Ordering Information
HI97115 is supplied with a sample cuvette (2 pcs.), sample cuvette cap (2 pcs.), 1.5V AA alkaline batteries (3 pcs.), instrument quality certificate, and Quick Reference Guide with QR code for instruction manual download.* CAL Check standards and testing reagents sold separately
HI97115C is…